Notice: get_translations was called incorrectly in /home/www/lab-integration.com/wp-content/themes/lotusmarketing/template-product.php on line 31: the call to $polylang->model->get_translations() has been deprecated in Polylang 1.8, use PLL()->model->post->get_translations() instead. Error handler in /home/www/lab-integration.com/wp-content/plugins/polylang/include/model.php on line 617

S-Type

S-type load cells have become very popular in recent years because of their low cost yet their performance in many situations can be similar to those of more complex design. The S in their type refers to their shape that can be associated with the letter S (or Z when you look at them the other way around).

Lab Integration offers a variety of S-type load cells and their difference lies primarily in their capacity, accuracy and level of robustness.


Notice: get_translations was called incorrectly in /home/www/lab-integration.com/wp-content/themes/lotusmarketing/template-product.php on line 52: the call to $polylang->model->get_translations() has been deprecated in Polylang 1.8, use PLL()->model->post->get_translations() instead. Error handler in /home/www/lab-integration.com/wp-content/plugins/polylang/include/model.php on line 617

Notice: get_translations was called incorrectly in /home/www/lab-integration.com/wp-content/themes/lotusmarketing/template-product.php on line 52: the call to $polylang->model->get_translations() has been deprecated in Polylang 1.8, use PLL()->model->post->get_translations() instead. Error handler in /home/www/lab-integration.com/wp-content/plugins/polylang/include/model.php on line 617

Notice: get_translations was called incorrectly in /home/www/lab-integration.com/wp-content/themes/lotusmarketing/template-product.php on line 52: the call to $polylang->model->get_translations() has been deprecated in Polylang 1.8, use PLL()->model->post->get_translations() instead. Error handler in /home/www/lab-integration.com/wp-content/plugins/polylang/include/model.php on line 617

Notice: get_translations was called incorrectly in /home/www/lab-integration.com/wp-content/themes/lotusmarketing/template-product.php on line 52: the call to $polylang->model->get_translations() has been deprecated in Polylang 1.8, use PLL()->model->post->get_translations() instead. Error handler in /home/www/lab-integration.com/wp-content/plugins/polylang/include/model.php on line 617

Notice: get_translations was called incorrectly in /home/www/lab-integration.com/wp-content/themes/lotusmarketing/template-product.php on line 52: the call to $polylang->model->get_translations() has been deprecated in Polylang 1.8, use PLL()->model->post->get_translations() instead. Error handler in /home/www/lab-integration.com/wp-content/plugins/polylang/include/model.php on line 617
KAS KAP-S TCE TS TCA
Capacity range2 kN – 50 kN5 N – 50 kN3.5 kN – 200 kN100 N – 75 kN10 N – 500 N
Operating ModeTension / CompressionTension / CompressionTension / CompressionTension / CompressionTension / Compression
Accuracy (% error of reading)0.1%, 0.05%0.2%, 0.1%, 0.05%0.2%, 0.1%0.2%, 0.1%0.2%
MaterialStainless SteelStainless Steel / Aluminum AlloyStainless SteelStainless SteelAluminum Alloy
Service Load120 %120 %120%120%120%
Operating Load150 %150 %150%150%150 %
DocumentationDocumentation
Breaking Load300 %300 %300 %300 %300 %
Transverse Load100 %, 10 % for accuracy50 %, 10 % for accuracy50 %100 %50 %
Dynamic Load50 %50 %50 %50 %50 %
Deformation at Nominal Load0.12 mm to 0.55 mm0.05 mm to 0.80 mm0.3 mm0.2 mm0.3 mm
Typical Excitation Voltage10 V10 V10 V10 V10 V
Excitation Voltage Range1 V to 18 V1 V to 18 V1 V to 18 V1 V to 18 V1 V to 18 V
Sensitivity2 mV/V ±0.002 mV/V2 mV/V ±0.002 mV/V2 mV/V ±0.002 mV/V2 mV/V ±0.002 mV/V2 mV/V ±0.002 mV/V
Input Resistance380 Ω ±30 Ω380 Ω ±30 Ω420 Ω ±20 Ω420 Ω ±20 Ω440 Ω ±20 Ω
Output Resistance352 Ω ± 1.5 Ω352 Ω ± 3 Ω350 Ω ± 2 Ω350 Ω ± 2 Ω350 Ω ± 2 Ω
Compensated Temperature Range-20 °C to +60 °C-20 °C to +60 °C-10 °C to +40 °C-10 °C to +40 °C-10 °C to +40 °C
Operating Temperature Range-30 °C to +70 °C-30 °C to +70 °C-20 °C to +70 °C-20 °C to +70 °C-20 °C to +70 °C
Storage Temperature Range-40 °C to +70 °C-40 °C to +70 °C-20 °C to +80 °C-20 °C to +80 °C-20 °C to +80 °C
Temperature Effect on Zero±0.035 %0.2 %, 0.1 %, 0.05 %±0.030 %±0.028 %±0.025 %
Temperature Effect on Sensitivity±0.1 %0.2 %, 0.1 %, 0.05 %±0.011 %±0.012 %±0.021 %
Cable Length3 m3 m5 m5 m3 m
Image